14
ENGLISH
The data and information shown in this dialogue may be changed by Came Cancelli Automatici S.p.A. at any time without prior warning.
7 Settings
A.C.T.
PAR.OP.
SLOW V. RUN S.
RUN V.
SLOW S.
SETTING TRIMMER LIST:
- «A.C.T.» Sets the waiting time while open. Once this time has elapsed, closing automatically takes place. The waiting time
may be set from 1 to 150 seconds.
- «PAR.OP.» Sets the gate’s partial opening. By pushing the partial opening button connected at 2-3P, the gate opens
depending on the length of the gate.
- «SLOW S.» Sets the amperometric sensitivity that controls the force generated by the motor during slow down; if the force
exceed the set level, the system intervenes by inverting the direction of motion.
- «RUN S.» Sets the amperometric sensitivity that controls the force generated by the motor during movement; if the force
exceeds the set level, the system intervenes by inverting the direction of motion.
- «SLOW V.» Sets the gate’s fi nal opening/closing phase slow-down speeds.
- «RUN V.» Sets the gate’s opening/closing motion speed.
LIST WARNINGS OF THE COMMAND AND SAFETY DEVICES’ CONTROL LEDs:
- «PROG» Red Led. Normally off.
When the transmitter is activating, it turns on or fl ashes.
- «PWR» Green led. Normally on.
Shows that card is properly powered;
- «1» Yellow led. Normally off.
Shows activation of the PARTIAL STOP button.
- «C1» Yellow led. Normally off.
Shows that there are obstacles between the photocells (which are in OPEN WHILE CLOSING mode).
- «C3» Yellow Led. Normally off.
Shows that there are obstacles between the photocells (which are in PARTIAL STOP mode).
- «C6» Yellow Led. Normally off.
Show obstacles detected by the sensitive edge (which are in OPEN WHILE CLOSING mode).
- «C7» Yellow Led. Normally off.
Shows obstacles detected by sensitive edge (which are in CLOSE WHILE OPENING mode).
8 Warning Led
Led C7
Led 1
Led C1
Led C3
Led C6
Led PWR
Led PROG