The data and information shown in this dialogue may be changed by Came Cancelli Automatici S.p.A. at any time without prior warning.
Terminals for powering the following accessories:
- 24V A.C. normally;
- 24V D.C. when the emergency batteries are
working;
Maximum allowed power: 37W


%
0
#
#
#
#
43
,
.
Power supply for accessories
+
-
230V (a.c.) Power, 50/60Hz
frequency
Cable lug with bolt and washer for connecting to earth.


%
0
#
#
#
#
43
Open-gate status light (contact range: 24V – 3W max)
- Signal that gate is open; turns off when gate is closed.
Movement fl ashing light (Contact range: 24V – 25W max)
- Flashes during the gate’s opening and closing phases.
Stop button (N.C. contact)
- Gate stop button. Excludes automatic closing. For motion to resume,
press the command button or the remote control button.
Key selector and/or command button (N.O. contact)
- Gate opening and closing command.
By pressing the button or turning the selector key, the gate
inverts its movement or stops depending on which the settings
on the DIP switches.
Key selector and/or partial opening button (N.O. contact)
- Partial gate opening for pedestrian access.
Command and control devices


%