2.5 - Wiring the Motors
Wire the gear motor by following the wiring diagram on the label which is fastened to the gear motor
(fig 13).
For the cable connection, use the appropriate cable clamp (part A) supplied, fixing it to the capacitor
support (part B).
2.6 - Wiring in the Safety Photocells
Safety beams should be fitted approximately 15 inches fom ground level.
If fitting a second arc line of safety beams then C & NC must be wired in series.
Fig
1
Ground
U
VW
Terminal block
U/XV/YW
Part. A
Part. B
Fig 13
TX
2
10 2 TX C NC
-
10
2
C1
Fig 14