5.1 Preliminary checks
Before proceeding with the installation, it is necessary to:
• Make sure the door is rigid and compact and that the sliding wheels are well oiled and in good condition.
• The ground guide must be well fastened to the ground, fully on the surface for the entirety of its length and without irregularities
that might obstruct the gate’s movement.
• The upper guide runners must not create friction.
• Provide for a gate stopper for opening and one for closing, and for the path of electrical cables as per standard system.
• Make sure the point in which the ratiomotor is fixed is in an area protected from shocks or bumps, and that the anchoring
surface is solid.
• Provide for suitable omnipolar disconnection device with more than 3 mm between contacts to section power supply.
• Connections inside the case made for protection circuit continuity are allowed as long as they include additional insulation
with respect to other internal drive parts.
• Install suitable tubes and ducts for electric cable passage to guarantee protection against mechanical damage.
Installation must be carried out by expert qualified personnel and in full observance of regulations in force.
5 Installation
5.2 Tools and materials
Make sure all tools and materials necessary are within reach to install the edge in maximum safety, according to regulations in
force. The following figure illustrates the minimum equipment for the installer.
N.B.: An evaluation of the size of the cables with lengths other than the data in the table must be made based on the effective
absorption of the connected devices, according to the instructions indicated by the CEI EN 60204-1 standards.
For connections that require several loads on the same line (sequential), the size given on the table must be re-evaluated based
on actual absorption and distances.
5.3 Cable list and minimun thickness
Connections Type of cable Length of cable 1 < 10 m Length of cable 10 < 20 m Length of cable 20 < 30 m
230V 2F power supply
FROR CEI
20-22
CEI EN
50267-2-1
3G x 1,5 mm
2
3G x 2,5 mm
2
3G x 4 mm
2
24V - 230V flashing lamp 2 x 0,5 mm
2
2 x 1 mm
2
2 x 1,5 mm
2
Photoelectric cells TX 2 x 0,5 mm
2
2 x 0.5 mm
2
2 x 0,5 mm
2
Photoelectric cells RX 4 x 0,5 mm
2
4 x 0,5 mm
2
4 x 0,5 mm
2
24V power supply accessory 2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 1 mm
2
Control button 2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
2
Antenna connection RG58 max. 10 m
4