T.C .A .
SENS.
FUS. MOTORE 8A
FUS.
ACC. 3,15A
FUS. CENTR. 630mA
T.C .A .
SENS.
FUS. MOTORE 8A
FUS.
ACC. 3,15A
FUS. CENTR. 630mA
SELECTION OF FUNCTIONS
10-way dip-switch
2-way dip-switch
1 ON Automatic closure enabled;
2 ON "Open-stop-close-stop” with pushbutton (2-7) and radio control (AF board inserted)
enabled;
2 OFF "Open-close” with pushbutton (2-7) and radio control (AF board inserted) enabled;
3 OFF "Only opening” with pushbutton (2-7) and radio control (AF board inserted) enabled;
4 ON Pre-flashing in opening and closing enabled; After an opening or closing command, the
flascher connected to the 10-E flashes for 5 seconds before beginning the procedure;
5 ON Obstacle detection device with motor of limit position enabled; when the motor is stopped
(gate is closed, open or half-open after an emergency stop command), the transmitter and
the control pushbutton will be deactivated if an obstacle is detected by one of the safety
devices (for example, the photocells);
6 ON "Operator present" enabled, gate operates only when the pushbutton is held down (the
radio remote control system is deactivated);
7 OFF Re-opening in closing phase enabled; connect the safety device on terminal (2-C1) the
photocells on detecting an obstacle while closing the door, cause the movement direction
to be reversed until opening is complete;
8 Not used, keep the dip in position «OFF»;
9 Not used, keep the dip in position «OFF»;
10 ON Enables the function of stopping while closing;
10 OFF Enables the function of slowing while closing;
1 ON Control unit enabled for V600 gear motor;
1 OFF Control unit enabled for V700 gear motor;
2 Not used, keep the dip in position «OFF»;